Lateral Earth Pressure: Rankine Active, At-Rest and Passive — A Worked Example with Water and Surcharge
Lateral earth pressure is the input to every retaining-wall, basement-wall and excavation-support check. Get it wrong and the overturning, sliding and bending checks that follow are wrong too. This guide gives the three standard states, how surcharge, groundwater and cohesion modify them, and two worked examples whose numbers you can verify by hand.
1. The three states
The horizontal effective stress is related to the vertical effective stress by a coefficient: σ'h = K · σ'v.
- Active (Ka) — the wall moves away from the soil enough to mobilize full shear strength. Lowest pressure. Rankine:
Ka = tan²(45° − φ'/2). - At rest (K0) — no wall movement (rigid basement walls, braced excavations). Jaky:
K0 = 1 − sin φ'for normally consolidated soil; for over-consolidated soil multiply byOCR^0.5(approximately). - Passive (Kp) — the wall pushes into the soil. Highest resistance. Rankine:
Kp = tan²(45° + φ'/2) = 1/Ka.
For φ' = 30°: Ka = 0.333, K0 = 0.500, Kp = 3.000. Note how much the state matters: at-rest pressure is 50% higher than active, and mobilizing passive resistance needs far more movement than mobilizing active pressure.
2. Adding surcharge, cohesion and water
- Uniform surcharge q adds a rectangular pressure
K · qover the full height. - Cohesion c' reduces active pressure:
σ'a = Ka·σ'v − 2c'√Ka. The result can be negative near the top (tension crack). Do not rely on tension: cut the diagram off at zero, and be careful about relying on c' at all in long-term design. - Groundwater: below the water table use the buoyant unit weight (γsat − γw) in σ'v for the earth pressure, and add the full hydrostatic pressure
u = γw·zseparately. Water pressure is not multiplied by Ka — it acts at full value and is often the largest part of the load.
3. Worked example A — dry backfill with surcharge
Wall height H = 6 m, backfill γ = 18 kN/m³, φ' = 30°, c' = 0, uniform surcharge q = 10 kPa, no water.
| Item | Calculation | Result |
|---|---|---|
| Active, soil | ½ · 0.333 · 18 · 6² | 108.0 kN/m (at H/3 = 2.00 m) |
| Active, surcharge | 0.333 · 10 · 6 | 20.0 kN/m (at H/2 = 3.00 m) |
| Total active thrust | 108 + 20 | 128.0 kN/m |
| Height of resultant | (108·2 + 20·3) / 128 | 2.16 m above base |
| Overturning moment about base | 108·2 + 20·3 | 276 kN·m/m |
| At-rest thrust (K0 = 0.5) | ½·0.5·18·6² + 0.5·10·6 | 162 + 30 = 192 kN/m |
| Passive over 1.5 m embedment | ½ · 3.0 · 18 · 1.5² | 60.8 kN/m |
The at-rest thrust is 1.5 times the active thrust. If your wall cannot move (for example a basement wall restrained by floor slabs), designing for active pressure is unconservative.
4. Worked example B — with a water table
Same wall (H = 6 m), φ' = 30°, c' = 0, no surcharge. Water table at 3 m depth. γ = 18 kN/m³ above the water table, γsat = 20 kN/m³ below, γw = 9.81 kN/m³.
- At 3 m: σ'v = 18·3 = 54 kPa → σ'a = 0.333 · 54 = 18.0 kPa.
- At 6 m: σ'v = 54 + (20 − 9.81)·3 = 84.57 kPa → σ'a = 0.333 · 84.57 = 28.19 kPa.
- Water pressure at 6 m: u = 9.81·3 = 29.43 kPa (zero at 3 m).
Split the diagram into pieces:
| Piece | Force (kN/m) | Height above base (m) |
|---|---|---|
| Upper triangle (0–3 m) | ½·18·3 = 27.0 | 4.00 |
| Rectangle (3–6 m) | 18·3 = 54.0 | 1.50 |
| Lower triangle (3–6 m) | ½·10.19·3 = 15.3 | 1.00 |
| Earth pressure subtotal | 96.3 | 2.12 |
| Water | ½·29.43·3 = 44.1 | 1.00 |
| Total | 140.4 kN/m | 1.77 |
Compare with the same wall, dry: ½·0.333·18·6² = 108 kN/m. Water at mid-height increases the total thrust by about 30% and lowers the line of action — the water part alone is 31% of the load. This is why drainage behind walls is not optional.
5. Common mistakes
- Using active pressure for a wall that cannot yield.
- Applying Ka to the water pressure.
- Using γsat instead of γ' (buoyant weight) for σ'v below the water table.
- Counting on the tension zone of a cohesive soil, or on passive resistance in the top metre (disturbed, seasonal) of the embedment.
- Ignoring wall friction without saying so. Rankine assumes a smooth vertical wall and level backfill; Coulomb handles wall friction and inclined backfill.
6. Doing it in a spreadsheet
The key is to split the pressure diagram exactly at layer boundaries and at the water table; otherwise the triangles and rectangles above are not integrated correctly. Our Lateral Earth Pressure Excel sheet does this for up to three soil layers — active (Rankine), at-rest (Jaky × OCR) and passive, with surcharge, groundwater and a tension cut-off for cohesion — and gives the total thrust, the height of the resultant and the moment about the base for your overturning and sliding checks. The two examples above are good test cases for any sheet you build or buy.
Related worked examples
- Bearing Capacity of a Square Footing — Terzaghi vs Meyerhof Worked Example
- Slope Stability by the Simplified Bishop Method — Worked Example
This article is an educational summary using Rankine theory. Verify design values against your governing code and project geotechnical report.
Lateral Earth Pressure Excel — Active, At-Rest and Passive with Groundwater, Surcharge and Cohesion
Enter up to 3 soil layers (unit weight, saturated weight, φ', c', OCR), surcharge and water-table depth to get active (Rankine), at-rest (Ja…
More guides
Proctor Compaction Test — Optimum Water Content and Maximum Dry Density Worked Example
Foundation Settlement Worked Example — Immediate and Consolidation Settlement
Bearing Capacity of a Square Footing — Terzaghi vs Meyerhof Worked Example
Slope Stability by the Simplified Bishop Method — Worked Example
Atterberg Limits Chart and USCS Classification — Four Worked Examples (CL, CH, ML, SC)
CPT-Based Liquefaction Triggering: The Simplified Method Step by Step, with a Worked Example