Seismic geotechnics

CPT-Based Liquefaction Triggering: The Simplified Method Step by Step, with a Worked Example

📅 2026-11-08⏱ 8 min read📶 Intermediate✍️ RastaWorks team

Cone penetration testing (CPT) gives a continuous, repeatable profile, which makes it the preferred input for liquefaction screening. The simplified (stress-based) method compares the cyclic stress the earthquake imposes with the cyclic resistance the soil can offer. This article walks through the method for one depth so you can see every number.

1. The idea

Liquefaction triggering is checked as a factor of safety:

FS = CRR7.5 · MSF · Kσ / CSR

FS < 1.0 means triggering is expected for that layer. Many codes require FS ≥ 1.1–1.3 or more.

2. Step 1 — Screen the soil type

Only soils that behave like sand can liquefy in the classic sense. Use the soil behaviour type index Ic (Robertson): layers with Ic > ~2.6 are generally clay-like and are not screened as liquefiable by this method (they may still lose strength — check separately). The example below is a clean sand with Ic ≈ 1.5, where the fines correction is not needed (Kc = 1).

3. Step 2 — Stresses

Water table at 2.0 m, γ = 18 kN/m³ above and 19 kN/m³ below, γw = 9.81 kN/m³. Evaluate at depth z = 6 m:

4. Step 3 — Normalized cone resistance

Measured qc = 7.0 MPa at 6 m. Normalize to 1 atmosphere (Pa = 101.3 kPa) with a stress exponent n = 0.5 (appropriate for clean sand; the full Robertson procedure iterates n with Ic):

qc1N = (qc/Pa) · (Pa/σ'v)0.5 = (7000/101.3) · (101.3/72.8)0.5 = 69.1 × 1.180 = 81.5

With Kc = 1 for clean sand, the equivalent clean-sand value is qc1Ncs = 81.5.

5. Step 4 — CRR for M7.5

Robertson & Wride correlation:

Here: CRR7.5 = 93 · (0.0815)³ + 0.08 = 0.130.

6. Step 5 — CSR from the earthquake

Design earthquake: peak ground acceleration amax = 0.30 g, magnitude Mw = 7.0.

7. Step 6 — Magnitude scaling and the factor of safety

Using the Idriss form MSF = 174 / Mw2.56: MSF = 174 / 72.56 = 1.19.

FS = CRR7.5 · MSF / CSR = 0.130 · 1.19 / 0.286 = 0.54

FS = 0.54 < 1: this layer is expected to liquefy under the design event. Repeating the calculation at every CPT reading (typically every 2 cm) and plotting FS against depth gives the liquefaction profile.

8. From FS to consequences

A thin liquefiable layer under a thick non-liquefiable crust may cause no surface damage; a thick one near the surface will. Standard follow-ups are the Liquefaction Potential Index (LPI), post-liquefaction settlement, and lateral spreading checks. These turn the FS profile into a severity class used for foundation decisions.

9. Limits of this method

10. Doing the whole profile in Excel

Our CPT Liquefaction Excel sheet takes your CPT data, water table and design earthquake and returns the liquefaction factor of safety, so you do not repeat the arithmetic above by hand at every depth. Use the worked example in this article as a check on any spreadsheet before you trust it.

Related worked examples

Educational article — not a substitute for a project-specific geotechnical investigation and code-compliant liquefaction assessment.

📈

CPT Liquefaction Triggering Excel — Robertson & Wride, FS and LPI

Enter CPT data (qc, fs and optional u2) to get, for every depth, the soil behaviour index Ic, clean-sand equivalent resistance, CSR, CRR, li…

View sheet

Questions? Chat on WhatsApp


More guides

Proctor Compaction Test — Optimum Water Content and Maximum Dry Density Worked Example

Foundation Settlement Worked Example — Immediate and Consolidation Settlement

Bearing Capacity of a Square Footing — Terzaghi vs Meyerhof Worked Example

Slope Stability by the Simplified Bishop Method — Worked Example

Atterberg Limits Chart and USCS Classification — Four Worked Examples (CL, CH, ML, SC)

Lateral Earth Pressure: Rankine Active, At-Rest and Passive — A Worked Example with Water and Surcharge