CPT-Based Liquefaction Triggering: The Simplified Method Step by Step, with a Worked Example
Cone penetration testing (CPT) gives a continuous, repeatable profile, which makes it the preferred input for liquefaction screening. The simplified (stress-based) method compares the cyclic stress the earthquake imposes with the cyclic resistance the soil can offer. This article walks through the method for one depth so you can see every number.
1. The idea
Liquefaction triggering is checked as a factor of safety:
FS = CRR7.5 · MSF · Kσ / CSR
- CSR — cyclic stress ratio: demand from the earthquake.
- CRR7.5 — cyclic resistance ratio for a magnitude-7.5 event: capacity of the soil, from CPT.
- MSF — magnitude scaling factor; Kσ — overburden correction (taken as 1.0 here for simplicity; it matters at depth).
FS < 1.0 means triggering is expected for that layer. Many codes require FS ≥ 1.1–1.3 or more.
2. Step 1 — Screen the soil type
Only soils that behave like sand can liquefy in the classic sense. Use the soil behaviour type index Ic (Robertson): layers with Ic > ~2.6 are generally clay-like and are not screened as liquefiable by this method (they may still lose strength — check separately). The example below is a clean sand with Ic ≈ 1.5, where the fines correction is not needed (Kc = 1).
3. Step 2 — Stresses
Water table at 2.0 m, γ = 18 kN/m³ above and 19 kN/m³ below, γw = 9.81 kN/m³. Evaluate at depth z = 6 m:
- Total vertical stress: σv = 18·2 + 19·4 = 112 kPa
- Pore pressure: u = 9.81·4 = 39.2 kPa
- Effective stress: σ'v = 112 − 39.2 = 72.8 kPa
4. Step 3 — Normalized cone resistance
Measured qc = 7.0 MPa at 6 m. Normalize to 1 atmosphere (Pa = 101.3 kPa) with a stress exponent n = 0.5 (appropriate for clean sand; the full Robertson procedure iterates n with Ic):
qc1N = (qc/Pa) · (Pa/σ'v)0.5 = (7000/101.3) · (101.3/72.8)0.5 = 69.1 × 1.180 = 81.5
With Kc = 1 for clean sand, the equivalent clean-sand value is qc1Ncs = 81.5.
5. Step 4 — CRR for M7.5
Robertson & Wride correlation:
- for 50 ≤ qc1Ncs < 160:
CRR7.5 = 93 · (qc1Ncs/1000)³ + 0.08 - for qc1Ncs < 50:
CRR7.5 = 0.833 · (qc1Ncs/1000) + 0.05
Here: CRR7.5 = 93 · (0.0815)³ + 0.08 = 0.130.
6. Step 5 — CSR from the earthquake
Design earthquake: peak ground acceleration amax = 0.30 g, magnitude Mw = 7.0.
- Depth reduction factor (simple linear form, z ≤ 9.15 m): rd = 1 − 0.00765·z = 1 − 0.00765·6 = 0.954
CSR = 0.65 · (amax/g) · (σv/σ'v) · rd = 0.65 · 0.30 · (112/72.8) · 0.954 = 0.286
7. Step 6 — Magnitude scaling and the factor of safety
Using the Idriss form MSF = 174 / Mw2.56: MSF = 174 / 72.56 = 1.19.
FS = CRR7.5 · MSF / CSR = 0.130 · 1.19 / 0.286 = 0.54
FS = 0.54 < 1: this layer is expected to liquefy under the design event. Repeating the calculation at every CPT reading (typically every 2 cm) and plotting FS against depth gives the liquefaction profile.
8. From FS to consequences
A thin liquefiable layer under a thick non-liquefiable crust may cause no surface damage; a thick one near the surface will. Standard follow-ups are the Liquefaction Potential Index (LPI), post-liquefaction settlement, and lateral spreading checks. These turn the FS profile into a severity class used for foundation decisions.
9. Limits of this method
- It is a screening-level procedure; project-level work should follow the current published procedures (e.g. Boulanger & Idriss; Robertson) and your governing code, with site-specific amax and magnitude from the hazard study.
- The example uses simplifications — fixed n = 0.5, Kσ = 1, linear rd — chosen so that every number can be checked by hand. Full procedures iterate Ic, use a variable n, apply Kσ, and use a depth-dependent rd that also depends on magnitude.
- Silty and clay-like layers (higher Ic) need the fines correction or separate cyclic-softening evaluation.
10. Doing the whole profile in Excel
Our CPT Liquefaction Excel sheet takes your CPT data, water table and design earthquake and returns the liquefaction factor of safety, so you do not repeat the arithmetic above by hand at every depth. Use the worked example in this article as a check on any spreadsheet before you trust it.
Related worked examples
- Bearing Capacity of a Square Footing — Terzaghi vs Meyerhof Worked Example
- Foundation Settlement Worked Example — Immediate and Consolidation Settlement
Educational article — not a substitute for a project-specific geotechnical investigation and code-compliant liquefaction assessment.
CPT Liquefaction Triggering Excel — Robertson & Wride, FS and LPI
Enter CPT data (qc, fs and optional u2) to get, for every depth, the soil behaviour index Ic, clean-sand equivalent resistance, CSR, CRR, li…
More guides
Proctor Compaction Test — Optimum Water Content and Maximum Dry Density Worked Example
Foundation Settlement Worked Example — Immediate and Consolidation Settlement
Bearing Capacity of a Square Footing — Terzaghi vs Meyerhof Worked Example
Slope Stability by the Simplified Bishop Method — Worked Example