Atterberg Limits Chart and USCS Classification — Four Worked Examples (CL, CH, ML, SC)
The Atterberg limits are the first thing you compute on any fine-grained soil. Two simple tests, the liquid limit and the plastic limit, give you the plasticity index, a position on the Casagrande plasticity chart and, with the grain-size data, the USCS group symbol (CL, CH, ML, SC and so on). This guide explains the chart, gives the classification rules and works four examples you can check by hand.
1. The three numbers
- Liquid limit (LL) — the water content at which the soil changes from plastic to liquid behaviour. In the Casagrande cup test (ASTM D4318) it is the water content at 25 blows read from a flow curve; a fall-cone test is the common alternative outside the USA.
- Plastic limit (PL) — the lowest water content at which the soil can be rolled into a thread about 3 mm in diameter without crumbling.
- Plasticity index (PI) —
PI = LL − PL, the water-content range over which the soil is plastic.
With the natural water content w you also get the liquidity index LI = (w − PL) / PI. LI near 0 means a stiff plastic clay; LI near 1 means the soil is close to its liquid limit.
2. The Atterberg limits chart (plasticity chart)
The plasticity chart used in the Unified Soil Classification System (ASTM D2487) plots PI against LL. Two reference lines matter:
A-line: PI = 0.73 (LL − 20) U-line: PI = 0.9 (LL − 8)
Points above the A-line plot as clays; points below it plot as silts (or organic soils). The U-line is the practical upper bound of natural soils: a point above it usually means a testing or calculation error. The vertical line at LL = 50 separates low plasticity (L) from high plasticity (H).
3. Naming a fine-grained soil
If more than 50% of the soil passes the No. 200 sieve, it is fine-grained. Then:
| Position on the chart | LL < 50 | LL ≥ 50 |
|---|---|---|
| On or above the A-line and PI > 7 | CL — lean clay | CH — fat clay |
| On or above the A-line and 4 ≤ PI ≤ 7 | CL-ML — silty clay | — |
| Below the A-line, or PI < 4 | ML — silt | MH — elastic silt |
Organic soils (OL, OH) are identified when the liquid limit of the oven-dried sample is less than 75% of the liquid limit of the sample that was never dried. This is why you must not oven-dry a sample before the Atterberg tests.
4. Worked example 1 — a lean clay
LL = 48, PL = 22, natural water content w = 30%, 65% passing the No. 200 sieve.
PI = 48 − 22 = 26 A-line at LL = 48: 0.73 × (48 − 20) = 20.4 LI = (30 − 22) / 26 = 0.31
PI = 26 plots above the A-line (20.4) and LL is below 50, so the soil is CL. LI = 0.31 means a fairly stiff plastic clay.
5. Worked example 2 — a fat clay
LL = 62, PL = 30, so PI = 32. The A-line at LL = 62 is 0.73 × 42 = 30.7. PI is above it and LL ≥ 50, so the soil is CH. Fat clays are typically more compressible and more prone to swelling and shrinkage, which should be reflected in the foundation design.
6. Worked example 3 — a silt with PI = 10
LL = 40, PL = 30, so PI = 10. The A-line at LL = 40 is 14.6. PI is below the A-line, so the soil is ML, a silt, even though PI is greater than 7. Naming the soil from PI alone would call it a clay; the chart position is what counts. Saturated low-plasticity silts can also be liquefiable.
7. Worked example 4 — a sand with fines
A sample has 15% gravel, 67% sand and 18% fines (passing the No. 200 sieve). The fines have LL = 30 and PL = 18.
- Coarse fraction = 82%. Gravel share of the coarse fraction = 15 / 82 = 18%, which is below 50%, so the soil is a sand (S).
- Fines of 18% exceed 12%, so the second letter comes from the plasticity of the fines: PI = 30 − 18 = 12, and the A-line at LL = 30 is 7.3.
- PI = 12 is above the A-line and greater than 7, so the fines are clayey: SC, clayey sand.
With 5–12% fines the soil gets a dual symbol (for example SW-SC); below 5% fines you choose between well- and poorly-graded using Cu and Cc (for sands, SW needs Cu ≥ 6 and 1 ≤ Cc ≤ 3).
8. Doing it in a spreadsheet
- Plasticity index:
=LL-PL - A-line:
=0.73*(LL-20) - Fine-grained symbol:
=IF(OR(PI<4,PI<0.73*(LL-20)),IF(LL<50,"ML","MH"),IF(LL>=50,"CH",IF(PI<=7,"CL-ML","CL"))) - Liquidity index:
=(w-PL)/PI
9. Common mistakes
- Oven-drying the sample before testing, which hides organic soils and changes LL.
- Mixing Casagrande-cup and fall-cone results in one report without stating the method.
- Rolling the plastic-limit thread thicker or thinner than 3 mm.
- Naming the soil from PI only, without checking the position relative to the A-line (example 3).
- Forgetting that coarse soils with 5–12% fines take a dual symbol.
Our Atterberg Limits and USCS Excel sheet does all of this: multipoint liquid limit, plastic limit, PI, LI, activity, the Casagrande chart with the A- and U-lines, and automatic USCS symbol and group name, including dual symbols. The four examples above are good test cases for any sheet you build or buy.
Related worked examples
- Proctor Compaction Test — Optimum Water Content and Maximum Dry Density Worked Example
- Foundation Settlement Worked Example — Immediate and Consolidation Settlement
This article is an educational summary based on ASTM D4318 and D2487. Use the edition specified for your project and the judgement of the engineer in charge for the final classification.
Atterberg Limits and USCS Classification Excel Sheet — LL, PL, PI and Plasticity Chart — Bilingual
Full Atterberg limits data reduction with live formulas: multipoint liquid limit flow curve, plastic limit, plasticity, liquidity and activi…
More guides
Proctor Compaction Test — Optimum Water Content and Maximum Dry Density Worked Example
Foundation Settlement Worked Example — Immediate and Consolidation Settlement
Bearing Capacity of a Square Footing — Terzaghi vs Meyerhof Worked Example
Slope Stability by the Simplified Bishop Method — Worked Example
CPT-Based Liquefaction Triggering: The Simplified Method Step by Step, with a Worked Example