Foundation Settlement Worked Example — Immediate and Consolidation Settlement
A foundation that is safe against shear failure can still be unusable if it settles too much. This guide works one complete settlement example by hand: a strip footing on a soft clay layer, with the immediate (elastic) settlement, the primary consolidation settlement, the time it takes, and the check against an allowable value. Every number can be reproduced in a spreadsheet, so you can check any tool you use against it. For the bearing-capacity half of the check, see the Terzaghi vs Meyerhof worked example.
1. The problem
- Strip footing, width B = 2 m, net contact pressure q = 100 kPa, flexible footing (centre point)
- Effective overburden stress at the base: q0 = 60 kPa
- One clay layer below the base: thickness H = 4 m, effective unit weight γ′ = 10 kN/m³, e0 = 0.9, Cc = 0.25, normally consolidated
- Elastic parameters for the immediate settlement: Es = 20 000 kPa, ν = 0.3
- Coefficient of consolidation cv = 2 m²/year, drained at top and bottom (double drainage)
- Allowable total settlement: 65 mm (a typical guide value for an isolated footing on clay)
2. Immediate (elastic) settlement
For a flexible footing, Si = q·B·(1 − ν²)·Iw / Es. For a strip footing (L/B = 100) the influence factor at the centre is Iw = 4.00. Then:
Si = 100 × 2 × (1 − 0.3²) × 4.00 / 20 000 = 0.0364 m = 36.4 mm
3. Primary consolidation settlement
Take the stress at the middle of the clay layer, z = 2 m below the base.
- Initial effective stress: σ′0 = q0 + γ′·H/2 = 60 + 10 × 2 = 80 kPa
- Stress increase from the footing, 2:1 distribution for a strip: Δσ = q·B/(B + z) = 100 × 2/(2 + 2) = 50 kPa
- Normally consolidated clay: Sc = Cc·H/(1 + e0)·log10[(σ′0 + Δσ)/σ′0] = 0.25 × 4/1.9 × log10(130/80) = 0.1110 m = 111.0 mm
4. Total settlement and the check
S = Si + Sc = 36.4 + 111.0 = 147.4 mm. This is more than twice the allowable 65 mm, so the design does not pass and the footing, the foundation type or the ground must be reconsidered. Secondary compression is not included, so the real long-term value is a little higher.
5. How fast does it settle?
The drainage path is Hdr = H/2 = 2 m. Time follows t = Tv·Hdr²/cv, with Tv = 0.197 at 50% and 0.848 at 90% consolidation:
- t50 = 0.197 × 2²/2 = 0.39 years (about 4.7 months)
- t90 = 0.848 × 2²/2 = 1.70 years
With single drainage the path is 4 m and the times are four times longer. The settlement at any time is S(t) = Si + U·Sc:
| Degree of consolidation U | Tv | Time t (years) | Settlement S(t) (mm) |
|---|---|---|---|
| 10% | 0.008 | 0.02 | 47 |
| 30% | 0.071 | 0.14 | 70 |
| 50% | 0.196 | 0.39 | 92 |
| 70% | 0.403 | 0.81 | 114 |
| 90% | 0.848 | 1.70 | 136 |
The 65 mm allowable value is passed when U ≈ 26%, which with these parameters is only about 1.3 months after loading. A settlement report that gives only the final number hides how soon the problem appears.
6. Two variations that change the answer
- If the clay were over-consolidated. Suppose the preconsolidation stress were σ′p = 150 kPa (an assumed value for illustration). Then σ′0 + Δσ = 130 kPa stays below it, and the recompression index applies: Sc = 0.05 × 4/1.9 × log10(130/80) = 22.2 mm, so S = 58.6 mm, which is within 65 mm. The same footing is a failure or a pass depending on whether the clay has been loaded before, which is why an oedometer test matters.
- If the footing is made wider for the same load. The load per metre is 100 × 2 = 200 kN/m. A footing with B = 3.33 m carries it at q = 60 kPa. For a flexible strip, Si depends on q·B, so it stays 36.4 mm, while Δσ at mid-layer drops to 37.5 kPa and Sc to 87.9 mm. The total is 124.3 mm: better, but still not enough. Widening alone does not fix a thick soft layer.
7. Reproduce it in a spreadsheet
Enter shape = Strip, B = 2, q = 100, Es = 20 000, ν = 0.3, q0 = 60, allowable = 65, drainage paths = 2, and one layer with H = 4, γ′ = 10, e0 = 0.9, Cc = 0.25, Cr = 0.05, σ′p blank (normally consolidated) and cv = 2. You should get Si = 36.4 mm, Sc = 111.0 mm, S = 147.4 mm, t50 = 0.39 years and t90 = 1.70 years.
8. Limits of this example
- One clay layer, a flexible footing and a 2:1 stress distribution at mid-layer. Thick layers should be split into thinner sub-layers, and rigid footings need a rigidity correction.
- The elastic modulus Es is the least certain input. Do not take it from SPT correlations for soft clay without a consolidation test.
- Differential settlement and angular distortion often govern more than total settlement. The 65 mm value here is a guide, not a code limit.
- Neighbouring footings, a falling water table or fill nearby add stress and settlement that this example does not include.
Our Foundation Settlement Excel sheet does the full calculation with live formulas: elastic settlement for strip, square, circular and rectangular footings, Terzaghi consolidation for up to 5 layers (normally and over-consolidated), 2:1 stress distribution, t50 and t90, a settlement–time curve and a printable A4 report. Use the worked example above to test any sheet or program: same inputs, same answer.
Related worked examples
- Bearing Capacity of a Square Footing — Terzaghi vs Meyerhof Worked Example
- Atterberg Limits Chart and USCS Classification — Four Worked Examples (CL, CH, ML, SC)
This article is an educational summary for preliminary checks. Final foundation design needs a site investigation, the criteria of your project and the judgement of the engineer in charge.
Foundation Settlement Excel Sheet — Immediate and Terzaghi Consolidation Settlement with Time — Bilingual
Total foundation settlement with live formulas: elastic immediate settlement, Terzaghi primary consolidation for up to 5 layers (normally an…
More guides
Proctor Compaction Test — Optimum Water Content and Maximum Dry Density Worked Example
Bearing Capacity of a Square Footing — Terzaghi vs Meyerhof Worked Example
Slope Stability by the Simplified Bishop Method — Worked Example
Atterberg Limits Chart and USCS Classification — Four Worked Examples (CL, CH, ML, SC)
CPT-Based Liquefaction Triggering: The Simplified Method Step by Step, with a Worked Example