Shallow foundations

Bearing Capacity of a Square Footing — Terzaghi vs Meyerhof Worked Example

📅 2026-11-14⏱ 8 min read📶 Intermediate✍️ RastaWorks team

Bearing-capacity formulas are easy to quote and easy to misapply. This guide works one complete example by hand: a square footing on a soil that has both cohesion and friction, with the Meyerhof and Terzaghi methods side by side and the water table in two positions. Every number can be reproduced in a spreadsheet, so you can check any tool you use against it.

1. The problem

WT, case BDf = 1.5 mB = 2.0 mq = γ·Df = 27 kPac′ = 10 kPa, φ′ = 30°γ = 18, γsat = 20 kN/m³WT, case A: far below ↓

The overburden at the base is q = γ·Df = 18 × 1.5 = 27 kPa. It is the same in both cases, because the soil above the base is above the water table.

2. Meyerhof method

The general equation is qu = c·Nc·sc·dc + q·Nq·sq·dq + 0.5·γ·B·Nγ·sγ·dγ. For φ′ = 30°:

Shape and depth factors (square footing, B/L = 1, φ′ > 10°):

Case A, water table far below. The three terms are:

So qu ≈ 1752 kPa and qall = qu/FS ≈ 584 kPa.

Case B, water table at the base. Only the self-weight term changes, because the soil below the base is now submerged: γ′ = γsat − 9.81 = 10.19 kN/m³. The term becomes 0.5 × 10.19 × 2.0 × 15.67 × 1.300 × 1.130 = 235 kPa, so qu ≈ 1572 kPa and qall ≈ 524 kPa.

3. Terzaghi method

For a square footing Terzaghi's equation is qu = 1.3·c·Nc + q·Nq + 0.4·γ·B·Nγ, with no depth factors: the soil above the base is treated only as a surcharge. For φ′ = 30°:

Case A: 1.3 × 10 × 37.16 + 27 × 22.46 + 0.4 × 18 × 2.0 × 19.7 = 483 + 606 + 284 ≈ 1373 kPa, so qall ≈ 458 kPa.

Case B: replace γ by γ′ = 10.19 kN/m³ in the last term: 483 + 606 + 161 ≈ 1250 kPa, so qall ≈ 417 kPa.

4. Results side by side

Methodqu, water far below (kPa)qall, FS = 3 (kPa)qu, water at base (kPa)qall, FS = 3 (kPa)
Meyerhof (with shape and depth factors)17525841572524
Terzaghi (square footing)13734581250417

5. Check against the applied load

Suppose the column load, including the footing weight, is Q = 1500 kN. The applied pressure is Q/(B·L) = 1500/4 = 375 kPa. The actual factor of safety is qu/qapplied:

The lowest value, 3.33, is above the required 3, so the footing passes in every combination. If a project reported only the most favourable value, it would hide how close the margin is in the worst case.

6. Reproduce it in a spreadsheet

Enter shape = Square, B = 2.0, Df = 1.5, c = 10, φ = 30, γ = 18, γsat = 20, FS = 3 and Q = 1500. Use a water-table depth of 99 m for case A and 1.5 m for case B. For Meyerhof, switch on the shape and depth factors; for Terzaghi, choose the Terzaghi method. You should get the values in the table above.

7. Limits of this example

Our Bearing Capacity Excel sheet does this calculation with live formulas: Meyerhof and Terzaghi side by side, strip, square, circular and rectangular footings, eccentricity, water table, general and local shear, and a printable A4 report. Use the worked example above to test any sheet or program: same inputs, same answer.

Related worked examples

This article is an educational summary for preliminary checks. Final foundation design needs a site investigation, the criteria of your project and the judgement of the engineer in charge.

🏛️

Shallow Foundation Bearing Capacity Excel Sheet — Terzaghi and Meyerhof with Water Table — Bilingual

Ultimate and allowable bearing capacity of strip, square, circular and rectangular footings with live formulas: Meyerhof and Terzaghi method…

View sheet

Questions? Chat on WhatsApp


More guides

Proctor Compaction Test — Optimum Water Content and Maximum Dry Density Worked Example

Foundation Settlement Worked Example — Immediate and Consolidation Settlement

Slope Stability by the Simplified Bishop Method — Worked Example

Atterberg Limits Chart and USCS Classification — Four Worked Examples (CL, CH, ML, SC)

Lateral Earth Pressure: Rankine Active, At-Rest and Passive — A Worked Example with Water and Surcharge

CPT-Based Liquefaction Triggering: The Simplified Method Step by Step, with a Worked Example